172 כל המחירים בקטלוג נקובים בשקל חדש ואינם כוללים מע״מ פתרונות למערכות פוטו וולטאיות 3 INVERTER PANEL LV CONNECTION Products and solutions for photovoltaic applications Surge protection devices type 2 - AC with plugin cartridge In=20kA Order code Pole Relay Number arrange- output of DIN ment modules n° VERSION WITH PLUG-IN CARTRIDGES. Rated discharge current In (8/20µs) 20kA per pole. SG21NA300 1P+N NO 2 SG21NA300R 1P+N YES 2 SG22PA300 2P NO 2 SG22PA300R 2P YES 2 SG23NA300 3P+N NO 4 SG23NA300R 3P+N YES 4 SG24PA300 4P NO 4 SG24PA300R 4P YES 4 Backup power supply for interface protection unit Order code Description Backup power supply for interface protection unit PMVF... PMVFUPS01 Input 230VAC. Output 230VAC with stored energy 200Ws and power 250VA Interface protection system for low voltage Order code Compliant with standards Low voltage system. PMVF51 CEI 0-21 PMVF60 DEWA DRRG and SEC (Saudi Electricity Company) PMVF70 ENA G59-3/G99 PMVF80 VDE-AR-N 4105 and VDE V 0126-1-1 Remote control and monitoring GSM modem via SMS Order Description code GSM modem (modular - 4U). IP69K outside aerial with 2.5m cable. RJ45-USB programming cable (included). EXCGSM01 100...240VAC, 1 digital input, 1 analogic input (0...10V, 0...20mA, NTC), 1 relay output, SMS send/ receive for remote control and alarm signals 4 pole contactors for photovoltaic applications BF series Order code AC3 operational data Ie current Max power ≤440V ≤400V ≤55°C ≤55°C [A] [kW] AC COIL. BF26T4A 26 13 BF38T4A 38 18,5 BF40T4A 40 18,5 BF50T4A 50 22 BF65T4A 65 30 BF80T4A 80 45 BF95T4A 95 55 BF115T4A 115 55 BF150T4A 150 75 BF160T4E 160 75 BF195T4E 195 90 BF230T4E 230 110 AC surge protection devices AC contactors (DDI) Energy meters Miniature and residual current circuit breakers Backup power supply GSM modem Interface protection system for low voltage DC AC LV/MV CONNECTION LOAD The order code must be completed with the winding voltage number (50/60Hz) and the winding voltage number followed by 60 if a 60Hz unit. The following standard voltages are available: – AC 50-60Hz 024 - 048 - 110 - 230 - 400V – AC 60Hz 024 60 - 048 60 - 120 60 - 220 60 - 230 60 - 460 60 - 575 60 (V). The contactor winding is electronically controlled; it can be either AC or DC powered and has a wide operational range. The order code must be completed with the winding voltage number. The following standard voltages are available: – AC/DC 024 = 24...60VAC/20...60VDC; 110 = 60...130VAC/DC; 230 = 100...250VAC/DC; 400 = 250...500V.
RkJQdWJsaXNoZXIy MjgzNzA=